01 / OEM replacement specification

Mitutoyo Digimatic Indicators & Digital Calipers (SR44 938882 vs CR2032 05SAA217) Battery Replacement Guide

Mitutoyo technical catalog Section F documents silver-oxide SR44 (part 938882) and lithium CR2032 (part 05SAA217) across precision Digimatic instruments.

Polarity & contact orientation

Install with the (+) stamped side facing up under the slide cover using non-conductive plastic tweezers.

Owner-manual replacement procedure

  1. Check your caliper or Digimatic indicator manual/compartment: standard absolute calipers and ID-C/ID-S indicators specify SR44 (Mitutoyo part 938882, silver oxide, ~7,000-20,000 hrs).
  2. Selected newer large-display Digimatic indicators specify a single 3 V CR2032 (part 05SAA217, ~12 months rated).
  3. Do not use cheap alkaline LR44 cells as a long-term substitute for silver-oxide SR44 where stable end-of-life voltage and leak prevention matter.

Verified OEM documentation

Mitutoyo · Precision Sensors & Indicators Catalog (Section F) — Mitutoyo Precision Catalog Section F (pp. 3-7)

Official Mitutoyo catalog specifying SR44 (part 938882, silver oxide, ~7,000-20,000 hrs) and CR2032 (part 05SAA217) across Digimatic indicators.

Inspect manufacturer document ↗

Type a battery code, alternate marking, or device name. Press Enter to open.