Multi-Function & High-Drain Watch Calibers (395/399, 392/384, 357/303) Battery Replacement Guide
SII documentation distinguishes paired same-size watch cells (395 vs 399, 392 vs 384, 357 vs 303) by continuous low-drain vs pulse high-drain design.
Trim / variant cellSR927SW · 1.55 VØ9.5 × 2.7 mm · Curve-ratedSilver oxide →Primary specified cellSR927W · 1.55 VØ9.5 × 2.7 mm · Curve-ratedSilver oxide →Trim / variant cellSR41SW · 1.55 VØ7.9 × 3.6 mm · Curve-ratedSilver oxide →Trim / variant cellSR41W · 1.55 VØ7.9 × 3.6 mm · Curve-ratedSilver oxide →Trim / variant cellSR44SW · 1.55 VØ11.6 × 5.4 mm · Curve-ratedSilver oxide →Trim / variant cellSR44W · 1.55 VØ11.6 × 5.4 mm · Curve-ratedSilver oxide →
Polarity & contact orientation
Always inspect tiny plastic battery insulator discs under the cell before reseating clamps.
Owner-manual replacement procedure
- Identify exact thickness: 395/399 (9.5 x 2.7 mm), 392/384 (7.9 x 3.6 mm), or 357/303 (11.6 x 5.4 mm).
- Check whether the caliber uses alarm, chronograph sub-dials, or EL backlights requiring high-drain W (399, 392, 357) over low-drain SW (395, 384, 303).
- Handle cells with insulated tweezers and lubricate/seat the caseback O-ring to keep water resistance.
Verified OEM documentation
Seiko Instruments · Silver-oxide watch battery cross-reference — Seiko Instruments Silver-Oxide Watch Cross-Reference (Drain-Class Chart)
Distinct low-drain vs high-drain designation and manufacturer codes; not device-specific equivalence approval.